Engineered Performance and Value
The k fluẍ® product in the Lydech fluẍ thermal and acoustical shields product family is designed for high temperature applications where superior and more thermally efficient materials are required. Through the combination of low emissivity metals and a high temperature low thermal conductivity insulating media, k fluẍ provides marked thermal isolation for sensitive components even when exhaust temperatures exceed 900 °C.
Metallic Layers
(a) Aluminum
0.1 to 2.5 mm
Flat or Embossed
1000, 3000 and 5000 Series Alloys
Lightweight
Excellent formability
Operating temperature < 300 °C
(i) Stainless Steel
0.1 to 2.5 mm
Flat or Embossed
Ferritic and Austenitic grades selected as a f(environment)
Operating Temperature < 1000 °C
(s) Aluminized Steel
0.25 to 1.0 mm
Flat or Embossed
Various coating weights and draw quality steels
Operating Temperature < 500 °C
Insulation Layer
(n) Lydall lambda
Thickness: 1.0 mm to 9.0 mm
High temperature chopped strand glass fiber
No shot content
Low organic content
Low thermal conductivity
Large diameter non-breathable fiber
Non-hazardous material 1999/45/EC compliant
Non-flammable
Thermal Performance
Low emissivity surfaces for high infrared radiation environments
High lateral thermal conductivity to spread heat away from hot zones
Low vertical thermal conductivity to increase the temperature drop across the shield
Acoustical Performance
High transmission loss for better acoustic isolation
Low vibration amplification for reduced noise contribution
Option to pierce/perforate for noise absorption
Mechanical Performance
Option to integrate straps and weld clips for quicker on-site assembly
Hemmed edges for handling safety and increased product robustness
Z-Folded edges for improved rigidity and completely sealed shielding unit
Data Sheet